SlimFit Commercial Condensing Gas Boiler

  • Default

    671x386_WM_slimfit_mainimage

  • Default

    671x386_WM_SlimFit_1A

  • Default

    671x386_WM_SlimFit_1B

  • Default

    671x386_WM_SlimFit_2

  • Default

    671x386_WM_SlimFit_3

  • Default

    671x386_WM_SlimFit_4

  • Default

    671x386_WM_SlimFit_5

  • Default

    671x386_WM_SlimFit_6

  • Default

    671x386_WM_SlimFit_8

  • Default

    671x386_WM_SlimFit_9

  • Default

    671x386_WM_SlimFit_Closeup

  • Default

    671x386_WM_SlimFit_Closeup_Controls

  • Default

    671x386_WM_SlimFit_Inside

  • Default

    671x386_WM_SlimFit_inside_closeup

  • Default

    671x386_Revit_Downloads

Image 1of 15
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
  • Default
Product Type:

commercial

SlimFit Commercial Condensing Gas Boiler
 
Where to Buy
Contact us today to obtain a contractor or distributor in your area.
LEARN MORE

Installs FAST, Built to LAST

  • Easy to Install - Designed for fast, easy installation in commercial and institutional settings
  • Easy to Own - Durable and reliable, ready for a lifetime of smooth operation
  • Right Fit for Retrofits - Fastest, easiest solution for limited-space retrofits
  • Up to 96.1% Combustion Efficiency
  • Up to 95.8% Thermal Efficiency
  • 1,000,000 TO 2,000,000 BTU/HR
  • Low NOx ‹ 20 PPM
  • Modulating Burner with 6:1 Turndown Ratio
  • CSD-1 Compliant is Standard
  • Fast & Easy Out of the Box Installation
  • High limit temperature control with manual reset, fixed 200 degree F
  • PVC, CPVC, PP or SS (AL29-4C) materials approved for Direct Vent and Direct Exhaust
  • Lightweight, Compact Design Packaged Boiler Requiring Minimal Clearance
  • SOLA-Control Flexibility with 7” LCD Touch Screen
  • Fully Customizable Outdoor Reset Curve
  • Lead/Lag Capability up to 8 Boilers with lead boiler rotation
  • Remote modulation through BAS using Modbus or BACnet
ModelAHRI Input Max (MBH)AHRI Input Min (MBH)AHRI Gross Output (MBH)Net AHRI (MBH)Combustion EfficiencyThermal EfficiencyVent MaterialVent Air SizeVent Air LengthMin Gas Pressure (w.c.)Max Gas Pressure (w.c.)Shipping Weight (lbs.)Length (in.)Width (in.)Height (in.)
SF10001,00016795883396.1%95.8%PVC, CPVC, PP or SS (AL29-4C)6" or 8"100' or 150'3"14"1,13077.9332.5651.87
SF15001,5002501,4371,25095.9%95.8%PVC, CPVC, PP or SS (AL29-4C)8"100'3"14"1,31077.9332.5651.87
SF20002,0003331,9061,65795.8%95.3%PVC, CPVC, PP or SS (AL29-4C)8"100'3"14"1,51090.1032.5651.87

Click here for information on Sentinel products

Introduction 

        

Unloading and Unpacking Boiler 

        

Boiler Components Overview 

        

Preparing Boiler Location 

        

Water Piping 

        

Venting and Air Intake 

        

Gas Piping 

        

Field Wiring 

        

SOLA Overview 

        

SOLA Controls Interface and Menus 

        

SOLA Controls Express Setup 

        

Start Up Procedures and Final Checks  

        

Maintenance 

        

Troubleshooting 

        

Summary